BALANCED VALVE FULL SEAL AT ZERO FLOW OPTIONAL MAXIMUM AND/OR MINIMUM PRESSURE SLAM-SHUT VALVE WIDE OUTLET-PRESSURE REGULATION RANGE ACCURATE PRESSURE REGULATION E140 serials regulator is a diaphragm and spring controlled direct acting regulator.Widely used in medium-sized commercial facilities and regional.Built-in with relief valve and ultra low-pressure safety devices.The regulator has characteristics of simple structure,convenient operation,easy maintenance online,etc. TECHNICAL ...
Well-designed Oxygen Gas Pressure Regulator - E140 SERIES PRESSURE REGULATORS – Ainuo Technology Detail:
BALANCED VALVE
FULL SEAL AT ZERO FLOW
OPTIONAL MAXIMUM AND/OR MINIMUM PRESSURE SLAM-SHUT VALVE
WIDE OUTLET-PRESSURE REGULATION RANGE
ACCURATE PRESSURE REGULATION
E140 serials regulator is a diaphragm and spring controlled direct acting regulator.Widely used in medium-sized commercial facilities and regional.Built-in with relief valve and ultra low-pressure safety devices.The regulator has characteristics of simple structure,convenient operation,easy maintenance online,etc.
TECHNICAL DATA
| Inlet pressure | Pemax.≤6 bar | |
| Shut-off when over-pressure | Who:22.5-450 mbar | |
| Inlet pressure range | Bpe: 0.5-5 bar | |
| Shut-off when low-pressure | Whu:12.8-250 mbar | |
| Outlet pressure set range | standard | Wh: 15-70 mbar |
| HP | Wh:70-300 mbar | |
| Shut-off accuracy | AG: ≤5% | |
| Accuracy class | AC: ±5% | |
| Response time | Ta: ≤1 sec | |
| Shut-off pressure class | SG: +10% | |
| Flow rate (natural gas) | Qmax. ≤900Nm³/h | |
| Operating temprature | -20℃-60℃ | |
| Connection size | DN50 PN16 | |
| Ambient temperature | -30℃-60℃ | |
| Weight | Low pressure type:19kgHigh pressure type:21kg | |
CAPACITY CHART
| Outletpressure
(mbar) |
Inlet pressure (bar) | ||||||||||||||
| 0.05 | 0.07 | 0.1 | 0.15 | 0.2 | 0.3 | 0.4 | 0.5 | 0.75 | 1 | 1.5 | 2 | 3 | 4 | ||
| STANDARD | 15 | 80 | 100 | 120 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 |
| 20 | 75 | 100 | 120 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
| 30 | 60 | 90 | 110 | 150 | 170 | 220 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
| 40 | - | 80 | 100 | 140 | 170 | 210 | 250 | 280 | 340 | 400 | 500 | 600 | 650 | 750 | |
| 50 | - | 70 | 90 | 140 | 160 | 210 | 240 | 270 | 340 | 400 | 500 | 600 | 650 | 750 | |
| 75 | - | - | 70 | 90 | 150 | 200 | 240 | 270 | 340 | 400 | 500 | 600 | 650 | 750 | |
|
AP |
100 | - | - | - | - | 140 | 190 | 230 | 250 | 340 | 400 | 500 | 600 | 650 | 750 |
| 150 | - | - | - | - | 100 | 170 | 220 | 250 | 330 | 390 | 500 | 600 | 650 | 750 | |
| 200 | - | - | - | - | - | 140 | 200 | 240 | 310 | 380 | 500 | 600 | 650 | 750 | |
| 300 | - | - | - | - | - | - | 150 | 210 | 310 | 380 | 500 | 600 | 650 | 750 | |
Capacities (cu.m./hr) are applicable to natural gas with a specific gravity of 0.702. For other gases, the values shown in the chart below must be multiplied by 0.595 for propane, 0.518 for butane, 0.755 for nitrogen and 0.744 for air.
OUTLINE DIMENSIONS (mm)
Product detail pictures:

Related Product Guide:
3 Basic Elements to Know About Your Gas Regulator
Quality Gas Regulators For A Safe Camping Trip
We support our buyers with ideal high quality products and high level service. Becoming the specialist manufacturer in this sector, we have gained rich practical experience in producing and managing for Well-designed Oxygen Gas Pressure Regulator - E140 SERIES PRESSURE REGULATORS – Ainuo Technology, The product will supply to all over the world, such as: Costa rica , The Swiss , Birmingham , With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!